# Combined Loading
Source: https://docs.clariti.site/calculations/combined-loading
How Clariti verifies anchor channels under combined tension and shear
Most real-world connections experience both tension and shear simultaneously. This page explains how Clariti checks the interaction between these load components.
## Why Interaction Matters
When tension and shear act together, the anchor capacity is reduced compared to either load acting alone:
```
Individual capacities:
Tension only: NRd = 20 kN
Shear only: VRd = 15 kN
Under combined loading:
If NEd = 10 kN and VEd = 10 kN
Are we safe? We need to check interaction.
```
Even though 10 kN \< 20 kN (tension OK) and 10 kN \< 15 kN (shear OK), the combined effect may exceed capacity.
## Interaction Equations
EN 1992-4 provides interaction equations depending on the failure mode being checked.
### Steel Failure Interaction
For steel failure (ductile mode):
```
(NEd/NRd,s)² + (VEd/VRd,s)² ≤ 1.0
```
This is a circular interaction — the most generous form.
### Concrete Failure Interaction
For concrete failure modes (cone, edge, pryout):
```
(NEd/NRd)^α + (VEd/VRd)^α ≤ 1.0
Where:
α = 1.5 for anchor channels (EN 1992-4)
```
### Linear Interaction (Conservative)
For simplified checking:
```
NEd/NRd + VEd/VRd ≤ 1.2
```
This is the most conservative approach and always acceptable.
## Interaction Diagrams
The interaction equations define curves (or surfaces) in N-V space:
```
N/NRd
│
1.0 ─┼─────────╮ ← Circular (α=2, steel)
│ ╲
│ ╲
│ ╲ ← α=1.5 (concrete)
│ ╲
│ ╲ ← Linear (α=1)
│ ╲
0.0 ─┼────────────────┼─── V/VRd
0 1.0
```
Points inside the curve: Design is adequate
Points on the curve: Utilization = 100%
Points outside: Design fails
## Which Mode to Check
Interaction must be checked for the governing failure modes in each direction:
| Tension Mode | Shear Mode | Check Interaction |
| ------------- | ------------- | ----------------- |
| Concrete cone | Concrete edge | Yes (α = 1.5) |
| Steel | Steel | Yes (α = 2) |
| Concrete cone | Pryout | Yes (α = 1.5) |
| Pullout | Steel | Yes (mixed) |
For mixed modes (e.g., concrete in tension, steel in shear), Clariti uses the more conservative interaction.
## Calculation Process
Clariti performs interaction checks as follows:
```
1. Calculate all tension utilizations
ηN,steel = NEd / NRd,s
ηN,cone = NEd / NRd,c
ηN,pull = NEd / NRd,p
etc.
2. Calculate all shear utilizations
ηV,steel = VEd / VRd,s
ηV,edge = VEd / VRd,c
ηV,pry = VEd / VRd,cp
3. Find governing modes
ηN,gov = max(ηN,steel, ηN,cone, ηN,pull, ...)
ηV,gov = max(ηV,steel, ηV,edge, ηV,pry)
4. Check interaction for governing combination
ηcombined = ηN,gov^α + ηV,gov^α
5. Also check other critical combinations
(e.g., steel-steel, cone-edge)
```
## Example Calculation
Given:
* NEd = 12 kN
* VEd = 8 kN
* NRd,c = 20 kN (concrete cone governs tension)
* VRd,c = 15 kN (concrete edge governs shear)
Check interaction (α = 1.5):
```
Tension utilization:
ηN = 12/20 = 0.60
Shear utilization:
ηV = 8/15 = 0.53
Combined utilization:
ηcombined = 0.60^1.5 + 0.53^1.5
ηcombined = 0.465 + 0.386
ηcombined = 0.85 ≤ 1.0 ✓
```
Design is adequate with 85% combined utilization.
Even if individual utilizations are moderate (60%, 53%), the combined
utilization can approach limits (85%). Always check interaction for
combined loading cases.
## Special Cases
### Tension-Only Connections
If VEd = 0:
```
ηcombined = ηN^α + 0 = ηN^α
```
For α = 1.5, this gives slightly lower utilization than the tension-only check. Clariti uses the governing (higher) value.
### Shear-Only Connections
If NEd = 0:
```
ηcombined = 0 + ηV^α = ηV^α
```
Similarly, shear-only connections use the direct shear utilization.
### Compression + Shear
When the axial load is compressive (toward concrete):
* No tension failure modes apply
* Compression improves shear capacity (friction)
* Clariti may credit friction per EN 1992-4
Friction credit requires verification that compression is permanent
and reliable. Conservative practice is to ignore friction benefit.
## Multiple Load Cases
Real connections may have multiple load combinations:
| Load Case | NEd | VEd |
| ------------------- | -------------- | -------------- |
| LC1: Dead + Live | 10 kN | 5 kN |
| LC2: Dead + Wind | 15 kN | 12 kN |
| LC3: Dead + Seismic | 8 kN | 18 kN |
Clariti checks interaction for each load case independently:
```
LC1: ηcombined = 0.50^1.5 + 0.33^1.5 = 0.54
LC2: ηcombined = 0.75^1.5 + 0.80^1.5 = 1.37 ✗ FAILS
LC3: ηcombined = 0.40^1.5 + 1.20^1.5 = 1.57 ✗ FAILS
```
LC2 and LC3 fail — a larger channel or additional anchors needed.
## In Clariti
Combined loading verification displays:
1. **Interaction diagram** — Visual plot showing design point
2. **Combined utilization** — Overall pass/fail with percentage
3. **Component breakdown** — N and V contributions
4. **Governing combination** — Which mode pairing controls
5. **Load case comparison** — Table showing all cases
The interaction diagram updates in real-time as you adjust loads or select different products, helping you find adequate solutions quickly.
## Key Takeaways
* Always check interaction under combined loading
* α = 1.5 for concrete modes, α = 2 for steel modes
* Combined utilization can be high even with moderate individual utilizations
* Check all load cases — different cases may govern
* Compression can improve shear capacity via friction (use with caution)
# Input Constraints
Source: https://docs.clariti.site/calculations/input-constraints
Valid input ranges and constraints for anchor channel calculations
This page documents the constraints that must be satisfied when specifying bolt positions and loads on anchor channels. Clariti validates these constraints automatically and warns you if inputs fall outside valid ranges.
## Channel Overhang Zone
Each anchor channel has an **overhang zone** at both ends where no bolt or load can be placed. This zone exists because the channel extends beyond the first and last anchors.
### Overhang Values
| Channel Family | Overhang x (mm) |
| -------------- | --------------- |
| CPRO38 | 25 |
| CPRO50 | 25 |
| CPRO52 | 35 |
| CPRO52S | 35 |
### Visual Representation
```
Channel layout:
│← x →│ │← x →│
═════╪═══════════════════════════════╪═════
│ │
First Last
anchor anchor
│ No │ ←────────── Valid bolt zone ────────→ │ No │
│loads│ │loads │
```
### Example
**CPRO50-350** (350mm length, overhang 25mm):
Bolts must be placed between 25mm and 325mm on this channel.
Loads placed in the overhang zone cannot be properly distributed to anchors and will produce invalid results. Clariti will reject such inputs.
## Minimum Bolt Spacing
When multiple bolts are used, they must maintain minimum spacing from each other. This ensures the force distribution model remains valid.
### Minimum Spacing Values
The minimum spacing between adjacent bolts depends on the bolt diameter:
| Channel | Bolt Size | Min Spacing Smin,cbo (mm) |
| -------------- | --------- | ------------------------- |
| CPRO38 | M10 | 50 |
| CPRO38 | M12 | 60 |
| CPRO38 | M16 | 80 |
| CPRO50 | M12 | 60 |
| CPRO50 | M16 | 80 |
| CPRO50 | M20 | 100 |
| CPRO52/CPRO52S | M12 | 60 |
| CPRO52/CPRO52S | M16 | 80 |
| CPRO52/CPRO52S | M20 | 100 |
### Rule
The spacing between any bolt and the end of the bolt group must be at least **5× the bolt diameter**.
### Example
Using M16 bolts on CPRO50:
* Minimum spacing = 80mm
* If Bolt 1 is at 100mm, Bolt 2 must be at ≥ 180mm
## Channel Length Constraints
Each channel family has minimum and maximum standard lengths.
### Length Ranges
| Channel Family | Min Length (mm) | Max Length (mm) | Source |
| -------------- | --------------- | --------------- | ------------ |
| CPRO38 | 100 | 3050 | ETA Table A3 |
| CPRO50 | 100 | 3050 | ETA Table A3 |
| CPRO52 | 150 | 3050 | ETA Table A3 |
| CPRO52S | 150 | 3050 | ETA Table A3 |
### Standard Variants
Channels come in predefined variants with specific anchor layouts:
**CPRO50 Example Variants:**
| Variant | Length | Anchors | Anchor Positions (mm) |
| ----------- | ------ | ------- | ----------------------- |
| CPRO50-100 | 100mm | 2 | 25, 75 |
| CPRO50-150 | 150mm | 2 | 25, 125 |
| CPRO50-200 | 200mm | 2 | 25, 175 |
| CPRO50-350 | 350mm | 3 | 25, 175, 325 |
| CPRO50-1050 | 1050mm | 5 | 25, 275, 525, 775, 1025 |
## Anchor Spacing Constraints
Anchor spacing varies by variant and must fall within allowed ranges.
### Spacing Limits
| Channel Family | Min Spacing Smin (mm) | Max Spacing Smax (mm) | Source |
| -------------- | --------------------- | --------------------- | ------------ |
| CPRO38 | 50 | 200 | ETA Table A3 |
| CPRO50 | 50 | 250 | ETA Table A3 |
| CPRO52 | 80 | 250 | ETA Table A3 |
Anchor spacing is fixed for each product variant. You cannot change anchor positions — select a variant that suits your application.
## Concrete Member Constraints
### Minimum Thickness
The concrete member must meet minimum thickness requirements:
| Channel | hmin (mm) | Source |
| ------- | --------- | ------------ |
| CPRO38 | 100 | ETA Table B1 |
| CPRO50 | 130 | ETA Table B1 |
| CPRO52 | 185 | ETA Table B1 |
| CPRO52S | 135 | ETA Table B1 |
Concrete thinner than hmin may not develop full cone breakout capacity. Additional splitting checks apply.
### Edge Distances
Edge distances affect concrete failure capacity:
* **Finite edges**: Specify actual distance (mm)
* **Infinite edges**: Use when edge is far enough to have no effect
The critical edge distance depends on embedment depth:
```
ccr,N = 1.5 × hef
```
| Channel | hef (mm) | ccr,N (mm) |
| ------- | -------- | ---------- |
| CPRO38 | 72 | 108 |
| CPRO50 | 99 | 149 |
| CPRO52 | 151 | 227 |
Edges closer than ccr,N reduce concrete capacity.
## Concrete Condition
The concrete condition significantly affects anchor capacity.
### Cracked vs Uncracked Concrete
| Condition | Description | Effect on Capacity |
| ------------- | ------------------------------------------- | ----------------------------- |
| **Cracked** | Concrete may have cracks at anchor location | Lower capacity (conservative) |
| **Uncracked** | Concrete verified to remain uncracked | Higher capacity |
Use "Cracked" unless you can demonstrate the concrete will remain uncracked under all load combinations. Most designs should assume cracked concrete.
### How It Affects Calculations
The cracking condition changes the k-factor used in concrete cone calculations:
| Channel | kcr,N (cracked) | kucr,N (uncracked) |
| ------- | --------------- | ------------------ |
| CPRO38 | 7.8 | 11.1 |
| CPRO50 | 8.1 | 11.6 |
| CPRO52 | 8.7 | 12.4 |
Uncracked concrete provides approximately 40% higher concrete cone capacity.
## Reinforcement Conditions
Reinforcement in the concrete member affects several failure mode calculations.
### Splitting Reinforcement
Controls the reinforcement factor (ψre,N) for concrete cone and splitting calculations.
| Option | Effect |
| --------------- | ---------------------------------------- |
| **Present** | ψre,N = 1.0 — Full concrete capacity |
| **Not present** | ψre,N = 0.5 + hef/200 — Reduced capacity |
Without splitting reinforcement, the reinforcement factor reduces capacity:
| Channel | hef (mm) | ψre,N (no reinforcement) |
| ------- | -------- | ------------------------ |
| CPRO38 | 72 | 0.86 |
| CPRO50 | 99 | 1.0 (capped) |
| CPRO52 | 151 | 1.0 (capped) |
### Edge Reinforcement
Controls the edge breakout capacity for shear loads acting toward edges.
| Option | Effect |
| --------------- | ---------------------------------- |
| **Present** | Higher shear capacity toward edges |
| **Not present** | Standard edge breakout calculation |
### Edge Geometry
When edge reinforcement is present, the geometry affects capacity:
| Option | Description |
| ------------------------------- | ----------------------------------------------- |
| **Straight edge with stirrups** | Stirrups provide confinement — highest capacity |
| **Straight edge (no stirrups)** | Edge reinforcement only — moderate improvement |
If your concrete has standard reinforcement cages with stirrups near edges, select "Straight edge with stirrups" for more accurate (less conservative) results.
## Compatible Bolts
Not all bolt sizes work with all channels. Use only compatible combinations:
| Channel | Compatible Bolts |
| ------- | ---------------- |
| CPRO38 | M10, M12, M16 |
| CPRO50 | M12, M16, M20 |
| CPRO52 | M12, M16, M20 |
| CPRO52S | M12, M16, M20 |
## Load Constraints
### Load Direction
* **Tension**: Must act away from concrete (pulling on anchor)
* **Shear**: Can act in any direction parallel to concrete surface
### Load Combinations
Clariti accepts:
* Tension only
* Shear only
* Combined tension and shear
Compression loads (pushing into concrete) are handled separately — the anchor channel does not resist compression, only the concrete bearing.
## Validation in Clariti
Clariti validates all inputs against these constraints:
| Constraint | Validation |
| ------------------------- | --------------------------------- |
| Bolt in overhang zone | Error — cannot proceed |
| Bolt spacing too small | Error — cannot proceed |
| Member too thin | Warning — splitting check applies |
| Edge too close | Warning — reduced capacity |
| Incompatible bolt/channel | Error — cannot proceed |
When constraints are violated, Clariti displays specific error messages explaining the issue and how to resolve it.
## Summary Table
| Parameter | CPRO38 | CPRO50 | CPRO52 | CPRO52S |
| -------------------- | ------- | ------- | ------- | :------ |
| Overhang x | 25mm | 25mm | 35mm | 35mm |
| Min channel length | 100mm | 100mm | 150mm | 150mm |
| Min anchor spacing | 50mm | 50mm | 80mm | 80mm |
| Max anchor spacing | 200mm | 250mm | 250mm | 250mm |
| Min member thickness | 100mm | 130mm | 185mm | 135mm |
| Embedment depth hef | 72mm | 99mm | 151mm | 101mm |
| Compatible bolts | M10-M16 | M12-M20 | M12-M20 | M12-M20 |
# Calculations Overview
Source: https://docs.clariti.site/calculations/overview
How Clariti performs EN 1992-4 verification for anchor channels
This section explains how Clariti calculates anchor channel capacity according to EN 1992-4. Understanding the methodology helps you interpret results and make informed design decisions.
## Supported Products
Clariti supports the following cast-in anchor channel systems:
| Channel Family | Description |
| -------------- | ------------------- |
| **CPRO38** | Light-duty channel |
| **CPRO50** | Medium-duty channel |
| **CPRO52** | Heavy-duty channel |
All calculations use certified values from **ETA-25/0222**.
## Design Philosophy
Clariti follows the limit state design approach of EN 1992-4:
```
NRd ≥ NEd
```
Where:
* NEd = Factored design load (input by you)
* NRd = Design resistance (calculated by Clariti)
The utilization ratio is:
```
β = NEd / NRd × 100%
```
A utilization ≤ 100% means the design is adequate for that failure mode.
## Calculation Flow
For each connection, Clariti performs these steps:
1. **Validate inputs** — Check bolt positions against constraints and verify channel/bolt compatibility
2. **Calculate influence length** — Determine which anchors are affected by each load
3. **Distribute forces to anchors** — Calculate how loads transfer to individual anchors
4. **Find worst-case loading** — Identify the critical bolt position that maximises anchor forces
5. **Calculate resistances** — Determine characteristic resistances (NRk, VRk) for each failure mode
6. **Apply safety factors** — Convert to design resistances (NRd = NRk / γM)
7. **Calculate utilization** — Compare demand to capacity (β = NEd / NRd)
8. **Check interaction** — For combined loading, verify interaction equation
9. **Report results** — Identify governing failure mode (highest utilization)
## Failure Modes
Anchor channels can fail in multiple ways. Clariti checks all applicable failure modes per EN 1992-4 Table 7.4 and reports the governing one (highest utilization).
### Tension Failure Modes
Per EN 1992-4:2018, anchor channels under tension must be verified against both steel and concrete failure modes.
#### Steel Failure Modes (Tension)
| Mode | Description | What It Checks |
| ----------------------------- | ------------------------------------------ | ------------------------------- |
| **Anchor in tension** | Fracture of anchor shaft | Anchor steel tensile capacity |
| **Anchor channel connection** | Failure of weld between anchor and channel | Connection strength |
| **Channel lips** | Local failure of channel lips | Lip bending capacity |
| **Channel bolt** | Fracture of the T-bolt | Bolt tensile capacity |
| **Channel in bending** | Flexural failure of channel | Channel bending moment capacity |
#### Concrete Failure Modes (Tension)
| Mode | Description | When Critical |
| ----------------- | -------------------------------------------- | -------------------------- |
| **Concrete cone** | Breakout of concrete cone around anchor | Most common governing mode |
| **Pullout** | Anchor pulls out without full cone formation | Related to bearing area |
| **Splitting** | Concrete splits due to wedging action | Thin members, close edges |
| **Blowout** | Side breakout near edges | Anchors close to edges |
### Shear Failure Modes
Per EN 1992-4:2018, anchor channels under shear must be verified against both steel and concrete failure modes.
#### Steel Failure Modes (Shear)
| Mode | Description | What It Checks |
| ----------------------------- | ------------------------------ | ------------------------- |
| **Anchor in shear** | Shear fracture of anchor | Anchor shear capacity |
| **Anchor channel connection** | Failure of connection in shear | Connection shear strength |
| **Channel bolt** | Shear failure of T-bolt | Bolt shear capacity |
#### Concrete Failure Modes (Shear)
| Mode | Description | When Critical |
| ----------------- | -------------------------- | ------------------------- |
| **Concrete edge** | Breakout toward free edge | Loads acting toward edges |
| **Pryout** | Back-side concrete failure | Short, stiff anchors |
### Combined Loading
When both tension and shear act simultaneously, Clariti checks interaction using EN 1992-4 equations. The combined utilization must also be ≤ 100%.
## Partial Safety Factors
Material partial factors from ETA-25/0222:
| Failure Mode | γM | Notes |
| --------------- | ---- | -------- |
| Steel — anchor | 1.85 | From ETA |
| Steel — channel | 1.8 | From ETA |
| Steel — bolt | 1.87 | From ETA |
| Concrete cone | 1.5 | Standard |
| Pullout | 1.5 | Standard |
| Splitting | 1.5 | Standard |
Clariti uses product-specific γM values from the ETA where available, which may differ from generic EN 1992-4 values.
## Transparency
Every calculation in Clariti can be expanded to show:
1. **Reference** — EN 1992-4 clause number
2. **Equation** — The formula being applied
3. **Inputs** — All values used with sources
4. **Factors** — Each ψ and γ factor with justification
5. **Result** — Step-by-step evaluation
This transparency allows you to:
* Verify calculations manually
* Understand why capacity is limited
* Explain results to checkers and approvers
* Learn the EN 1992-4 methodology
## Further Reading
[Valid ranges for bolt positions and loads →](/calculations/input-constraints)
[Detailed tension failure mode calculations →](/calculations/tension-verification)
[Detailed shear failure mode calculations →](/calculations/shear-verification)
[Interaction checks for combined forces →](/calculations/combined-loading)
# Shear Verification
Source: https://docs.clariti.site/calculations/shear-verification
Detailed explanation of shear failure mode calculations per EN 1992-4
This page explains how Clariti verifies anchor channels against shear failure modes according to EN 1992-4.
## Overview
Three shear failure modes must be checked:
1. **Steel failure** — Shear failure of anchor steel
2. **Concrete edge failure** — Breakout toward a free edge
3. **Concrete pryout** — Breakout on the back side of anchors
The governing mode depends on geometry, particularly edge distances and load direction.
## Steel Failure in Shear
### Equation
```
VRd,s = VRk,s / γMs
Where:
VRk,s = k₂ × As × fuk
```
| Symbol | Description | Source |
| -------------- | -------------------------- | ----------------------------- |
| k₂ | Reduction factor for shear | 0.6 (typical) |
| As | Stressed cross-section | ETA data |
| fuk | Ultimate steel strength | ETA data |
| γMs | Partial factor for steel | ETA (typically 1.0 for shear) |
### Notes
* Shear steel resistance is typically lower than tension (k₂ = 0.6)
* Lever arm effects may further reduce capacity
* Product-specific values in ETA may differ
### Lever Arm Effect
When shear acts with a lever arm (stand-off installation):
```
VRd,s = αM × VRk,s / γMs
Where:
αM = lever arm reduction factor
```
For cast-in anchor channels, lever arm is typically zero (no stand-off).
## Concrete Edge Failure
### When It Governs
Edge failure typically governs when:
* Shear acts toward a free edge
* Edge distance is less than \~10 × hef
* High shear loads relative to tension
### Equation
```
VRd,c = V°Rk,c × (Ac,V / A°c,V) × ψs,V × ψh,V × ψec,V × ψα,V × ψre,V / γMc
```
### Basic Resistance (V°Rk,c)
```
V°Rk,c = k₁ × dnom^α × √(lf/dnom) × √fck × c₁^1.5
Where:
k₁ = 1.7 (cracked) or 2.4 (uncracked)
dnom = nominal anchor diameter
lf = effective length under shear (≤ 8×dnom)
c₁ = edge distance in load direction
```
### Reference Area (A°c,V)
```
A°c,V = 4.5 × c₁²
Actual area Ac,V reduced by:
- Member thickness limitations
- Spacing to adjacent anchors
- Corner effects (two edges)
```
### Reduction Factors
**Edge distance factor (ψs,V)**:
```
ψs,V = 0.7 + 0.3 × c₂/(1.5×c₁) ≤ 1.0
```
Where c₂ is the perpendicular edge distance.
**Thickness factor (ψh,V)**:
```
ψh,V = (1.5×c₁/h)^0.5 ≤ 1.0
```
Applies when member thickness h \< 1.5 × c₁.
**Eccentricity factor (ψec,V)**:
```
ψec,V = 1/(1 + 2×eV/(3×c₁)) ≤ 1.0
```
**Load direction factor (ψα,V)**:
```
ψα,V = √(1/(cos²αV + (sin²αV)/2.5)) ≤ 1.0
```
Where αV is the angle between load and edge.
**Reinforcement factor (ψre,V)**:
```
ψre,V = 1.0 (with edge reinforcement)
ψre,V = 0.7 (without edge reinforcement, narrow member)
```
### Example Calculation
Given:
* c₁ = 150 mm (edge distance in load direction)
* c₂ = 200 mm (perpendicular edge)
* h = 300 mm (member thickness)
* fck = 30 MPa
* dnom = 10 mm, lf = 80 mm
* Cracked concrete
Calculate:
```
Reference area:
A°c,V = 4.5 × 150² = 101,250 mm²
Ac,V = Limited by geometry... (assume no reduction)
Ratio = 1.0
Edge factor (c₂ direction):
c₂/(1.5×c₁) = 200/(1.5×150) = 0.89
ψs,V = 0.7 + 0.3 × 0.89 = 0.97
Thickness factor:
1.5×c₁ = 225 mm < h = 300 mm
ψh,V = 1.0 (no reduction)
Basic resistance:
V°Rk,c = 1.7 × 10^0.5 × √(80/10) × √30 × 150^1.5
V°Rk,c = 1.7 × 3.16 × 2.83 × 5.48 × 1837
V°Rk,c = 153 kN
Design resistance:
VRd,c = 153 × 1.0 × 0.97 × 1.0 × 1.0 × 1.0 × 1.0 / 1.5
VRd,c = 99 kN
```
Edge failure is often the governing mode for shear toward edges. Always
check edge distances carefully and consider if reinforcement can be added.
## Concrete Pryout Failure
### When It Applies
Pryout governs for:
* Short, stiff anchors (hef \< 60mm typically)
* Shear away from edges
* High concrete strength (concrete cone capacity is high)
### Equation
```
VRd,cp = k × NRd,c
Where:
k = pryout factor
= 1.0 for hef < 60mm
= 2.0 for hef ≥ 60mm
NRd,c = concrete cone resistance (tension)
```
### Logic
Pryout is related to concrete cone because the failure mechanism involves a concrete breakout on the opposite side from the shear load. The pryout factor k accounts for the different loading geometry.
### Example
Given:
* hef = 50 mm
* NRd,c = 20 kN (from tension calculation)
Calculate:
```
k = 1.0 (since hef = 50 < 60mm)
VRd,cp = 1.0 × 20 = 20 kN
```
For deeper embedment (hef = 80 mm):
```
k = 2.0
VRd,cp = 2.0 × 20 = 40 kN
```
Pryout resistance doubles when embedment exceeds 60mm. This is a significant
threshold for anchor channel selection.
## Shear Load Direction
The governing failure mode depends heavily on load direction:
| Direction | Likely Governing Mode |
| ---------------- | ------------------------------- |
| Toward near edge | Concrete edge failure |
| Away from edges | Pryout or steel |
| Parallel to edge | Steel (often), or edge if close |
| Oblique | Check all modes |
Clariti automatically evaluates all modes for any load direction and reports the governing one.
## Governing Failure Mode
```
Utilization for each mode:
ηsteel = VEd / VRd,s
ηedge = VEd / VRd,c
ηpryout = VEd / VRd,cp
Governing mode = max(ηsteel, ηedge, ηpryout)
```
## In Clariti
Shear verification displays:
1. **Load direction** — Visual indicator of shear relative to edges
2. **Edge distances** — All edge distances with critical values
3. **Mode breakdown** — Each mode with utilization
4. **Governing indicator** — Highlighted governing mode
5. **Expanded calculations** — Full EN 1992-4 equations with values
The 3D view shows the shear vector and proximity to edges, helping you understand why certain modes govern.
# Tension Verification
Source: https://docs.clariti.site/calculations/tension-verification
Detailed explanation of tension failure mode calculations per EN 1992-4
This page explains how Clariti verifies anchor channels against tension failure modes according to EN 1992-4.
## Overview
Four tension failure modes must be checked:
1. **Steel failure** — Fracture of anchor or channel steel
2. **Concrete cone failure** — Breakout of concrete cone
3. **Pullout failure** — Anchor pulls out without cone formation
4. **Concrete splitting** — Splitting of concrete member
Each mode has characteristic resistance (NRk) reduced by partial factors (γM) to give design resistance (NRd).
## Verification Format
All verifications follow the same format:
```
βN = Nᵃₑd / NRd ≤ 1.0
```
Where:
* βN = Utilisation ratio (shown as percentage)
* Nᵃₑd = Design tension force on anchor (from [force distribution](/calculations/force-distribution))
* NRd = Design resistance for the failure mode
A utilisation ≤ 100% means the design is adequate for that failure mode.
## Steel Failure — Anchor in Tension
This failure mode occurs when the tension load exceeds the tensile strength of the anchor shaft, causing it to fracture.
### Equation
```
NRd,s,a = NRk,s,a / γMs
```
### Parameters
| Symbol | Description | CPRO38 | CPRO50 | CPRO52 | Source |
| ------- | ------------------------------------------- | ------- | ------- | ------- | ------------ |
| NRk,s,a | Characteristic tensile resistance of anchor | 27.1 kN | 42.4 kN | 71.7 kN | ETA Table C1 |
| γMs | Partial safety factor for steel | 1.85 | 1.85 | 1.85 | ETA Annex C1 |
### Design Resistances
| Channel | NRk,s,a (kN) | γMs | NRd,s,a (kN) |
| ------- | ------------ | ---- | ------------ |
| CPRO38 | 27.1 | 1.85 | **14.6** |
| CPRO50 | 42.4 | 1.85 | **22.9** |
| CPRO52 | 71.7 | 1.85 | **38.8** |
### Worked Example
**Given**: CPRO50 channel, anchor tension Nᵃₑd = 13.90 kN
**Step 1**: Look up characteristic resistance
* NRk,s,a = 42.4 kN (from ETA Table C1)
**Step 2**: Apply partial safety factor
```
NRd,s,a = 42.4 / 1.85 = 22.92 kN
```
**Step 3**: Calculate utilisation
```
βN = 13.90 / 22.92 = 0.61 = 61%
```
**Result**: Verification **PASSES** (61% ≤ 100%)
## Steel Failure — Channel Connection
This mode checks the connection between anchor and channel (the weld or mechanical connection).
### Equation
```
NRd,s,c = NRk,s,c / γMs,ca
```
### Parameters
| Symbol | Description | CPRO38 | CPRO50 | CPRO52 | Source |
| ------- | --------------------------------------- | ------ | ------ | ------ | ------------ |
| NRk,s,c | Characteristic resistance of connection | 28 kN | 32 kN | 76 kN | ETA Table C1 |
| γMs,ca | Partial safety factor | 1.8 | 1.8 | 1.8 | ETA Annex C1 |
## Steel Failure — Channel Bolt
The T-bolt connecting the load to the channel must also be verified.
### Equation
```
NRd,s,b = NRk,s,b / γMs2
```
### Bolt Characteristic Resistances
| Bolt Size | CPRO38 | CPRO50 | CPRO52 | Source |
| --------- | -------- | -------- | -------- | ------------ |
| M10 | 40.6 kN | — | — | ETA Table C7 |
| M12 | 45.7 kN | 59 kN | 59 kN | ETA Table C7 |
| M16 | 101.7 kN | 109.9 kN | 109.9 kN | ETA Table C7 |
| M20 | — | 145.2 kN | 145.2 kN | ETA Table C7 |
Partial safety factor: γMs2 = 1.87
## Concrete Cone Failure
### Equation
```
NRd,c = N⁰Rk,c × (Ac,N / A⁰c,N) × ψs,N × ψre,N × ψec,N / γMc
```
### Basic Resistance
```
N⁰Rk,c = k × √fck × hef^1.5
```
Where:
| Symbol | Description | Cracked | Uncracked | Source |
| ------ | --------------- | ------- | --------- | ------------ |
| k | Cracking factor | kcr,N | kucr,N | ETA Table C2 |
**Cracking factors by channel:**
| Channel | kcr,N | kucr,N | hef (mm) |
| ------- | ----- | ------ | -------- |
| CPRO38 | 7.8 | 11.1 | 72 |
| CPRO50 | 8.1 | 11.6 | 99 |
| CPRO52 | 8.7 | 12.4 | 151 |
### Area Ratio
The reference cone area assumes unlimited concrete:
```
A⁰c,N = scr,N × scr,N
```
Where scr,N = 3 × hef
The actual area Ac,N is reduced by:
* Proximity to edges
* Overlap with adjacent anchors
* Member thickness limitations
### Reduction Factors
**Edge distance factor:**
```
ψs,N = 0.7 + 0.3 × (c / ccr,N) ≤ 1.0
```
Where ccr,N = 1.5 × hef
**Reinforcement factor:**
```
ψre,N = 0.5 + hef/200 ≤ 1.0 (without supplementary reinforcement)
ψre,N = 1.0 (with supplementary reinforcement)
```
**Eccentricity factor:**
```
ψec,N = 1 / (1 + 2eN/scr,N) ≤ 1.0
```
**Partial factor:** γMc = 1.5
## Pullout Failure
### Equation
```
NRd,p = NRk,p × ψc,p / γMp
```
### Characteristic Resistances
| Channel | Cracked NRk,p (kN) | Uncracked NRk,p (kN) | Source |
| ------- | ------------------ | -------------------- | ------------ |
| CPRO38 | 13.6 | 19.0 | ETA Table C2 |
| CPRO50 | 18.4 | 25.8 | ETA Table C2 |
| CPRO52 | 32.2 | 45.1 | ETA Table C2 |
**Partial factor:** γMp = 1.5
Pullout resistance is product-specific and determined by testing. Clariti uses certified ETA values directly.
## Concrete Splitting
### When It Applies
Splitting must be checked when:
* Member thickness h \< hmin (specified in ETA)
* Edge distance c \< ccr,sp
* Spacing s \< scr,sp
### Minimum Member Thickness
| Channel | hmin (mm) | Source |
| ------- | --------- | ------------ |
| CPRO38 | 100 | ETA Table B1 |
| CPRO50 | 130 | ETA Table B1 |
| CPRO52 | 185 | ETA Table B1 |
### Equation
```
NRd,sp = N⁰Rk,c × (Ac,N/A⁰c,N)sp × ψs,N × ψre,N × ψec,N × ψh,sp / γMsp
```
**Thickness factor:**
```
ψh,sp = (h / hmin)^(2/3) ≤ 1.0
```
**Partial factor:** γMsp = 1.5
## Safety Factors Summary
| Failure Mode | Symbol | Value | Source |
| ------------------------- | -------- | ----- | ------------ |
| Anchor steel failure | γMs | 1.85 | ETA Annex C1 |
| Anchor channel connection | γMs,ca | 1.8 | ETA Annex C1 |
| Channel lips | γMs,l | 1.8 | ETA Annex C1 |
| Tension bolt | γMs2 | 1.87 | ETA Annex C1 |
| Channel flexure | γMs,flex | 1.15 | ETA Annex C1 |
| Pullout | γMp | 1.5 | ETA Annex C2 |
| Splitting | γMsp | 1.5 | ETA Annex C2 |
| Concrete cone/blowout | γMc | 1.5 | ETA Annex C2 |
## Governing Failure Mode
Clariti determines the governing mode automatically:
```
ηsteel = NEd / NRd,s
ηcone = NEd / NRd,c
ηpull = NEd / NRd,p
ηsplit = NEd / NRd,sp
Governing mode = max(ηsteel, ηcone, ηpull, ηsplit)
```
The results panel highlights the governing mode and shows utilisation for all modes.
## In Clariti
Clariti displays tension verification as:
1. **Summary** — Overall tension utilisation and governing mode
2. **Breakdown** — Each mode with its utilisation percentage
3. **Expanded view** — Full calculation with all intermediate values
4. **ETA references** — Source data for traceability
All factors and their values are shown with the equation that generated them, allowing full verification of the calculation.
# Sharing & Collaboration
Source: https://docs.clariti.site/documentation/getting-started/user-and-org-setting
Share projects and designs with your team and manage organization settings.
## Organization Structure
Clariti uses an organization-based structure for collaboration. All team members belong to an organization (e.g., "CFS"), and sharing happens within this organizational context.
## Sharing Projects with Your Organization
To share a project with all members of your organization:
1. Navigate to the Projects list
2. Find the project you want to share
3. Click the Share icon (branching icon) next to the project
4. The project will now be visible to all organization members
Shared projects display a "Shared" label with a group icon, making it easy to identify collaborative work.
## Sharing Individual Designs
Designs can also be shared at the individual level:
1. Open the project containing the design
2. Find the design in the list
3. Click the Share icon next to the design name
4. The design will show "Shared" status instead of your name
## Understanding Sharing Status
In the designs list, the "Created by" column indicates sharing status:
* **"Shared" with group icon**: Visible to all organization members
* **User name with avatar**: Private to the creator (not shared with organization)
# Organisation Settings
## Managing Team Members
Organization administrators can add team members through Organization Settings:
1. Click on your organization name in the left sidebar (top)
2. Select Organization Settings
3. Navigate to the Members tab
4. Click Invite to add new team members by email
The Organization Settings panel includes:
* **General**: Organization profile and name settings
* **Members**: View, invite, and manage team members
## Deleting Your Account
A user can delete there organisiton from by clicking on the delete organisation. This will delete the account for all members.
## Leaving Your Organisiton
A user can remove themself from organisiton from by clicking on the leave organisation. This will delete the account for user from the account.
# User Settings
## Profile Settings
A user can change there email address and connected accounts to Clariti in the profile settings.
## Changing Password and Deleting Account
A user can change their password and delete their account in the security settings.
# Design Method
Source: https://docs.clariti.site/en-1992-4/design-methods
The EN 1992-4 design method used by Clariti for anchor channel verification
Clariti uses **Method A** from EN 1992-4 — the full design method that provides the most accurate verification of anchor channel capacity.
## Method A — Full Design Method
Method A is the complete verification procedure covering all failure modes with detailed calculations. It provides the highest accuracy and is required for final design verification.
### Procedure
The method follows these steps:
1. **Determine effective geometry**
* Embedment depth (hef)
* Edge distances (c1, c2)
* Spacing (s)
* Member thickness (h)
2. **Calculate characteristic resistances**
* Steel: NRk,s, VRk,s
* Concrete cone: NRk,c
* Pullout: NRk,p
* Splitting: NRk,sp
* Edge: VRk,c
* Pryout: VRk,cp
3. **Apply reduction factors**
* Area ratios (Ac,N/A°c,N)
* ψ factors (edge, spacing, eccentricity, etc.)
4. **Apply partial safety factors**
* NRd = NRk / γM
* VRd = VRk / γM
5. **Verify design condition**
* NEd ≤ NRd for all tension modes
* VEd ≤ VRd for all shear modes
6. **Check interaction**
* Combined tension-shear if applicable
### Why Method A
| Advantage | Benefit |
| ------------------ | -------------------------------------- |
| Most accurate | Reflects actual anchor behavior |
| All failure modes | No modes overlooked |
| Geometric effects | Accounts for edges, spacing, thickness |
| Optimised designs | Avoids unnecessary conservatism |
| Full documentation | Complete audit trail for approvals |
EN 1992-4 also defines simplified methods (B and C) for quick checks, but these are conservative and limited in scope. Clariti uses Method A exclusively to ensure accurate, optimised designs.
## How Clariti Implements Method A
Clariti automates the full Method A procedure:
1. **Automatic geometry analysis** — Determines all relevant distances and checks constraints
2. **Complete mode checking** — Verifies all applicable tension and shear failure modes
3. **Factor calculation** — Computes all ψ reduction factors with justification
4. **Interaction verification** — Checks combined loading per EN 1992-4 Section 7.2.3
5. **Transparency** — Documents every step with EN 1992-4 clause references
This ensures designs are:
* Fully compliant with EN 1992-4
* Optimised for the specific geometry
* Documented for approval
# Load Combinations
Source: https://docs.clariti.site/en-1992-4/load-combinations
Understanding load combinations for anchor channel design per Eurocode
Load combinations determine the design loads (NEd, VEd) that Clariti uses for verification. This page explains how loads are combined according to Eurocode principles.
## Load Combination Framework
EN 1990 defines how actions (loads) are combined for structural design. These combinations produce the design loads input to Clariti.
### Ultimate Limit State (ULS)
The primary design verification:
```
Ed = γG·Gk + γQ·Qk,1 + Σ(γQ·ψ0,i·Qk,i)
Where:
Gk = characteristic permanent action
Qk,1 = dominant variable action
Qk,i = other variable actions
γG = partial factor for permanent (1.35)
γQ = partial factor for variable (1.5)
ψ0 = combination factor
```
### Serviceability Limit State (SLS)
For deflection and durability checks:
```
Characteristic: Ed = Gk + Qk,1 + Σ(ψ0,i·Qk,i)
Frequent: Ed = Gk + ψ1,1·Qk,1 + Σ(ψ2,i·Qk,i)
Quasi-permanent: Ed = Gk + Σ(ψ2,i·Qk,i)
```
## Common Load Cases
### Dead Load (G)
Permanent, constant loads:
* Self-weight of structure
* Fixed equipment
* Permanent fixtures
Factor: γG = 1.35 (unfavorable) or 1.0 (favorable)
### Live Load (Q)
Variable loads from occupancy:
| Category | Example | ψ0 | ψ1 | ψ2 |
| ------------ | ------------- | ------------- | ------------- | ------------- |
| A (Domestic) | Residential | 0.7 | 0.5 | 0.3 |
| B (Office) | Commercial | 0.7 | 0.5 | 0.3 |
| C (Assembly) | Public spaces | 0.7 | 0.7 | 0.6 |
| D (Retail) | Shops | 0.7 | 0.7 | 0.6 |
### Wind Load (W)
Variable environmental load:
| Parameter | Value |
| ------------- | ----- |
| ψ0 | 0.6 |
| ψ1 | 0.2 |
| ψ2 | 0.0 |
Wind typically produces horizontal (shear) loads on anchor connections.
### Snow Load (S)
Variable environmental load (altitude dependent):
| Altitude | ψ0 | ψ1 | ψ2 |
| -------- | ------------- | ------------- | ------------- |
| \< 1000m | 0.5 | 0.2 | 0.0 |
| > 1000m | 0.7 | 0.5 | 0.2 |
### Temperature (T)
Thermal actions:
| Parameter | Value |
| ------------- | ----- |
| ψ0 | 0.6 |
| ψ1 | 0.5 |
| ψ2 | 0.0 |
Temperature changes can induce restraint forces in fixed connections.
## ULS Combination Equations
### Equation 6.10 (General)
```
Ed = 1.35·Gk + 1.5·Qk,1 + 1.5·Σ(ψ0,i·Qk,i)
```
Single equation covering all permanent and variable actions.
### Equations 6.10a and 6.10b (Alternative)
Some National Annexes use:
```
6.10a: Ed = 1.35·Gk + 1.5·ψ0·Qk,1 + 1.5·Σ(ψ0,i·Qk,i)
6.10b: Ed = ξ·1.35·Gk + 1.5·Qk,1 + 1.5·Σ(ψ0,i·Qk,i)
Where ξ = 0.85 (typical)
```
Use the more critical result.
Check your National Annex for which approach applies. Clariti accepts
factored design loads regardless of the combination method used.
## Worked Example
Facade bracket supporting a cladding panel:
### Input Loads (Characteristic)
| Action | Vertical (Tension) | Horizontal (Shear) |
| ----------------------- | ------------------ | ------------------ |
| Dead load Gk | 8 kN | 0 kN |
| Wind Wk | 0 kN | 12 kN |
| Live Qk | 2 kN | 0 kN |
### Combination 1: Dead + Wind (Primary)
```
NEd = 1.35 × 8 + 1.5 × 0.7 × 2 = 12.9 kN
VEd = 1.5 × 12 = 18.0 kN
```
### Combination 2: Dead + Live (Primary)
```
NEd = 1.35 × 8 + 1.5 × 2 = 13.8 kN
VEd = 1.5 × 0.6 × 12 = 10.8 kN
```
### Design Loads
Both combinations should be checked. The governing combination may differ depending on which failure mode controls.
## Load Direction Considerations
### Tension vs. Compression
* **Tension (away from concrete)**: Engages anchor capacity
* **Compression (into concrete)**: May provide friction benefit
### Shear Direction
* **Toward edge**: Concrete edge failure likely governs
* **Away from edge**: Pryout or steel may govern
* **Parallel to edge**: Direction affects capacity
### Sign Convention
In Clariti:
* Positive NEd: Tension (anchor in tension)
* Negative NEd: Compression (toward concrete)
* VEd: Specify direction relative to edges
## Special Situations
### Seismic Loading
Seismic combinations per EN 1998:
```
Ed = Gk + AEd + ψ2·Qk
Where AEd = seismic action
```
Partial factors may be modified for seismic design situations.
Seismic design requires additional considerations per EN 1992-4
Annex C. Products must be qualified for seismic applications.
### Accidental Loading
For accidental design situations (impact, explosion):
```
Ed = Gk + Ad + ψ1·Qk,1 + Σ(ψ2,i·Qk,i)
Where Ad = accidental action
```
Partial factors γ = 1.0 for accidental combinations.
### Fatigue Loading
For cyclic loading:
* Reduced partial factors may apply
* Fatigue verification per EN 1992-4 Section 4.4
* Product-specific fatigue data required
## In Clariti
### Load Input
Clariti expects factored design loads:
1. **Single load case**: Enter NEd and VEd directly
2. **Multiple cases**: Define several load cases, check each
### What to Enter
| Input Field | What to Enter |
| -------------- | --------------------------------- |
| NEd | Factored design tension (kN) |
| VEd | Factored design shear (kN) |
| Direction | Shear direction relative to edges |
### Multiple Load Cases
For comprehensive verification:
1. Create load cases for each combination
2. Clariti checks all modes for each case
3. Results show which case governs
4. Export includes all cases
If unsure which combination governs, enter multiple cases. Clariti
will identify the critical one for each failure mode.
# EN 1992-4 Overview
Source: https://docs.clariti.site/en-1992-4/overview
Introduction to EN 1992-4 and its application in anchor channel design
EN 1992-4 is the European standard governing the design of fastenings for use in concrete. This page provides an overview of the standard and how Clariti implements it.
## What is EN 1992-4?
**EN 1992-4:2018** (*Design of fastenings for use in concrete*) is a harmonized European standard that defines:
* Design methods for concrete fasteners
* Verification procedures for all failure modes
* Partial safety factors and reliability requirements
* Product qualification criteria
It replaced the previous ETAG 001 guidelines and is part of the Eurocode system (specifically, part of EC2).
## Scope
The standard covers:
Anchor channels, headed studs, and other fasteners placed before concrete is poured. These are Clariti's primary focus.
Mechanical anchors, chemical anchors, and undercut anchors installed in hardened concrete.
### What's Covered
* Fasteners under static, quasi-static, and fatigue loading
* Tension, shear, and combined loading
* Cracked and uncracked concrete
* Single fasteners and groups
### What's Not Covered
* Seismic design (see EN 1992-4 Annex C or national annexes)
* Fire design (see EN 1992-1-2)
* Fasteners in lightweight concrete (special provisions)
* Fibre reinforced concrete (requires additional guidance)
## Document Structure
EN 1992-4 is organized as follows:
| Section | Content |
| ------- | ------------------------------------------------ |
| 1-3 | Scope, references, definitions |
| 4 | Basis of design |
| 5 | Determination of action effects |
| 6 | Cast-in headed fasteners |
| **7** | **Anchor channels** (primary Clariti reference) |
| 8 | Post-installed mechanical fasteners |
| 9 | Post-installed chemical fasteners |
| Annexes | National parameters, seismic provisions, testing |
## Design Philosophy
EN 1992-4 follows limit state design principles consistent with other Eurocodes:
### Ultimate Limit State (ULS)
Verification that the design resistance exceeds the design action:
```
Ed ≤ Rd
Where:
Ed = design value of action (factored load)
Rd = design value of resistance (factored capacity)
```
All failure modes must satisfy this inequality.
### Serviceability Limit State (SLS)
Verification of:
* Displacement limits
* Crack width control
* Durability requirements
Clariti primarily addresses ULS verification. SLS checks (deflection, fatigue) may require additional analysis outside the tool.
## Material Assumptions
The standard assumes:
**Concrete:**
* Normal weight concrete (density 2000-2600 kg/m³)
* Strength classes C12/15 to C90/105
* Cracked or uncracked state
**Steel:**
* Carbon steel or stainless steel
* Defined by characteristic yield and ultimate strength
* Ductility requirements for certain applications
**Grout/Mortar:**
* Where applicable, must meet specified strength requirements
## Cracked vs. Uncracked Concrete
A critical design assumption:
| Condition | Assumption | When to Use |
| --------- | ---------- | ------------------------------------------- |
| Cracked | k₁ = 8.9 | Default — assume cracking occurs |
| Uncracked | k₁ = 12.7 | Only when cracking can be reliably excluded |
**Uncracked concrete** may be assumed only when:
* Tension zone is always in compression (prestressed elements)
* Detailed analysis proves no cracking occurs under SLS loads
* Member is designed to remain uncracked throughout its life
Most structural applications should assume cracked concrete. Using uncracked values without justification is unconservative and may not be accepted by checking engineers.
## Product Qualification
Anchor channels must have:
* **ETA (European Technical Assessment)** — Product-specific approval
* **CE marking** — Conformity to European standards
* **Declaration of Performance** — Manufacturer's declared properties
Clariti only includes products with valid ETAs, ensuring all resistance values are certified and traceable.
## National Annexes
EN 1992-4 allows national variation through National Annexes (NAs). Key nationally determined parameters include:
* Partial safety factors (γM values)
* Design working life assumptions
* Seismic provisions
* Additional requirements for specific applications
Clariti uses the recommended values from the base standard. Check your jurisdiction's National Annex for any modifications.
## Relationship to Other Standards
EN 1992-4 interfaces with:
| Standard | Interface |
| ----------- | --------------------------------------------- |
| EN 1990 | Basis of structural design, load combinations |
| EN 1991 | Actions on structures (load values) |
| EN 1992-1-1 | Concrete design (material properties) |
| EN 1993-1-1 | Steel design (for steel elements) |
| EN 1998-1 | Seismic design |
Design loads (NEd, VEd) come from EN 1991 analysis. Clariti focuses on the resistance side per EN 1992-4.
## Further Reading
* [Safety Factors](/en-1992-4/safety-factors) — Detailed partial factor information
* [Design Methods](/en-1992-4/design-methods) — Verification approaches
* [Load Combinations](/en-1992-4/load-combinations) — How loads are combined
* [Partial Factors](/en-1992-4/partial-factors) — γ values for different modes
# Partial Factors
Source: https://docs.clariti.site/en-1992-4/partial-factors
Complete reference for partial factors used in EN 1992-4 calculations
This page provides a comprehensive reference for all partial factors (γ) used in EN 1992-4 anchor channel calculations.
## Purpose of Partial Factors
Partial factors account for:
* **Material variability** — Scatter in material properties
* **Model uncertainty** — Differences between theory and reality
* **Geometric tolerances** — Installation and manufacturing variations
* **Consequence of failure** — Reliability requirements
The overall safety format:
```
Ed ≤ Rd = Rk / γM
Where γM accounts for resistance uncertainties
```
## Resistance Partial Factors (γM)
### Steel Failure Modes
| Application | Symbol | Recommended | Notes |
| ----------------------- | -------------- | ----------- | ----------------------- |
| Tension, fyk | γMs | 1.0 | Yield strength basis |
| Tension, fuk | γMs | 1.2 | Ultimate strength basis |
| Shear | γMs | 1.0 | Standard |
| Combined | γMs | 1.2 | Conservative |
Product ETAs may specify different γMs values. Always check the ETA for the specific product being used.
### Concrete Failure Modes
| Failure Mode | Symbol | Recommended | EN 1992-4 Reference |
| --------------- | -------------- | ----------- | ------------------- |
| Concrete cone | γMc | 1.5 | Table 4.1 |
| Concrete edge | γMc | 1.5 | Table 4.1 |
| Concrete pryout | γMc | 1.5 | Table 4.1 |
### Other Failure Modes
| Failure Mode | Symbol | Recommended | Notes |
| ------------ | --------------- | ----------- | -------------------------- |
| Pullout | γMp | 1.5 | Product-specific available |
| Splitting | γMsp | 1.5 | Standard |
| Blow-out | γMc | 1.5 | If applicable |
## Complete Factor Table
Reference table for all modes:
| Mode | Characteristic | Partial Factor | Design Resistance |
| ------------- | ----------------- | --------------------- | ----------------------------------------- |
| Steel tension | NRk,s | γMs = 1.2 | NRd,s = NRk,s/1.2 |
| Concrete cone | NRk,c | γMc = 1.5 | NRd,c = NRk,c/1.5 |
| Pullout | NRk,p | γMp = 1.5 | NRd,p = NRk,p/1.5 |
| Splitting | NRk,sp | γMsp = 1.5 | NRd,sp = NRk,sp/1.5 |
| Steel shear | VRk,s | γMs = 1.0 | VRd,s = VRk,s/1.0 |
| Concrete edge | VRk,c | γMc = 1.5 | VRd,c = VRk,c/1.5 |
| Pryout | VRk,cp | γMc = 1.5 | VRd,cp = VRk,cp/1.5 |
## Reduction Factors (ψ)
In addition to γ factors, various ψ factors reduce characteristic resistances:
### Tension ψ Factors
| Factor | Symbol | Purpose | Typical Range |
| -------------- | ----------------- | ------------------- | ------------- |
| Edge effect | ψs,N | Edge disturbance | 0.7 - 1.0 |
| Eccentricity | ψec,N | Non-uniform loading | 0.5 - 1.0 |
| Reinforcement | ψre,N | Supplementary steel | 0.5 - 1.0 |
| Shell spalling | ψucr,N | Uncracked benefit | 1.0 - 1.4 |
### Shear ψ Factors
| Factor | Symbol | Purpose | Typical Range |
| ------------- | ---------------- | ------------------- | ------------- |
| Edge effect | ψs,V | Perpendicular edge | 0.7 - 1.0 |
| Thickness | ψh,V | Member depth | 0.7 - 1.0 |
| Eccentricity | ψec,V | Non-uniform loading | 0.5 - 1.0 |
| Direction | ψα,V | Load angle to edge | 0.7 - 1.0 |
| Reinforcement | ψre,V | Edge reinforcement | 0.7 - 1.0 |
## National Annex Variations
National Annexes can modify recommended γM values:
### Typical Variations
| Country | Variation |
| -------------------------- | ----------------------------- |
| Germany (DIN EN 1992-4/NA) | Generally follows recommended |
| UK (BS EN 1992-4/NA) | Follows recommended values |
| France (NF EN 1992-4/NA) | Some modifications |
| Spain (UNE EN 1992-4/NA) | Generally follows recommended |
Always verify applicable National Annex for your project jurisdiction. Clariti uses recommended values by default.
## Product-Specific Factors
ETAs may specify different factors based on testing:
### When ETA Values Differ
| Situation | Action |
| ------------------------ | --------------------------------- |
| ETA γM higher | Use ETA value (more conservative) |
| ETA γM lower | Use ETA value (test-validated) |
| No ETA value | Use EN 1992-4 recommended |
Clariti automatically uses product-specific factors when available in the database.
## Consequence Classes
EN 1990 defines consequence classes affecting reliability:
| Class | Description | γ Modification |
| ----- | ---------------- | --------------------- |
| CC1 | Low consequence | May reduce by \~10% |
| CC2 | Medium (default) | Standard values |
| CC3 | High consequence | May increase by \~10% |
Most building applications use CC2. Modification factors KFI apply to actions, not resistances.
## Durability Factors
For corrosion and environmental exposure:
| Exposure | Consideration |
| ------------ | ------------------------------------ |
| Internal dry | Standard factors |
| External | Material selection (stainless steel) |
| Aggressive | Specialist assessment required |
Durability is typically addressed through material selection rather than factor modification.
## Fire Design
For fire design situations:
| Parameter | Fire Design |
| ---------------- | ---------------------- |
| γM,fi | Reduced (often 1.0) |
| Loads | Accidental combination |
| Resistance | Temperature-reduced |
Fire design follows EN 1992-1-2. Clariti focuses on ambient temperature design.
## In Clariti
### Factor Display
Clariti shows all factors in calculations:
1. **Summary view**: Shows resulting design resistance
2. **Expanded view**: Shows Rk, γM, and Rd = Rk/γM
3. **ψ factors**: Each factor listed with value and source
### Factor Source
For each factor, Clariti indicates:
* EN 1992-4 reference (recommended values)
* ETA reference (product-specific values)
* Which value was used and why
# Safety Factors
Source: https://docs.clariti.site/en-1992-4/safety-factors
Understanding partial safety factors in EN 1992-4 anchor channel design
Safety factors in EN 1992-4 ensure adequate reliability by accounting for uncertainties in material strength, loading, and calculation models. This page explains the factors used in anchor channel design.
## Limit State Design Framework
EN 1992-4 follows the Eurocode reliability framework:
```
Design resistance = Characteristic resistance / Partial factor
Rd = Rk / γM
```
Where:
* **Rk** = Characteristic (5% fractile) resistance
* **γM** = Partial safety factor for materials
* **Rd** = Design resistance
## Partial Factors for Resistance (γM)
### Steel Failure Modes
| Mode | Symbol | Recommended Value | Notes |
| ------------------ | -------------- | ----------------- | ------------------------ |
| Tension (yielding) | γMs | 1.0 | When fyk used |
| Tension (ultimate) | γMs | 1.2 | When fuk used |
| Shear | γMs | 1.0 | Standard value |
| Combined | γMs | 1.2 | Conservative |
Product ETAs may specify different γMs values. Clariti uses product-specific factors where provided in the ETA.
### Concrete Failure Modes
| Mode | Symbol | Recommended Value | Notes |
| ----------------------- | -------------- | ----------------- | -------------- |
| Concrete cone (tension) | γMc | 1.5 | Standard value |
| Concrete edge (shear) | γMc | 1.5 | Standard value |
| Concrete pryout | γMc | 1.5 | Standard value |
### Pullout and Splitting
| Mode | Symbol | Recommended Value | Notes |
| --------- | --------------- | ----------------- | ------------------- |
| Pullout | γMp | 1.5 | May vary by product |
| Splitting | γMsp | 1.5 | Standard value |
## Why Different Factors?
Partial factors reflect uncertainty and consequences:
### Steel Factors (Lower)
* Material properties well-controlled
* Manufacturing tolerances tight
* Failure mode typically ductile
* Good correlation between test and theory
### Concrete Factors (Higher)
* Greater variability in concrete strength
* Sensitivity to installation quality
* Brittle failure modes
* Complex interaction with surrounding concrete
## Characteristic Values
Characteristic resistance (Rk) represents the 5% fractile:
```
Rk = mean resistance - 1.64 × standard deviation
```
This means 95% of samples exceed Rk. Combined with γM, the design resistance has the target reliability index.
### Determination Methods
| Source | How Rk is Determined |
| ----------- | ---------------------------------------------- |
| Testing | Statistical evaluation of test results |
| Calculation | EN 1992-4 equations with characteristic inputs |
| ETA data | Product-specific values from approval testing |
Clariti uses ETA values where available, supplemented by EN 1992-4 calculations.
## Load Factors (γF)
Load factors (from EN 1990) increase design loads:
| Action Type | Symbol | Typical Value |
| ----------------------- | ------------- | ------------- |
| Permanent (unfavorable) | γG | 1.35 |
| Variable (unfavorable) | γQ | 1.5 |
| Permanent (favorable) | γG | 1.0 |
Clariti expects factored (design) loads as input. Apply load factors before entering NEd and VEd.
## Safety Factor Summary Table
Complete reference for standard values:
| Failure Mode | γM | Applies To |
| --------------- | ------------- | ----------------- |
| Steel tension | 1.2 | NRk,s |
| Steel shear | 1.0 | VRk,s |
| Concrete cone | 1.5 | NRk,c |
| Pullout | 1.5 | NRk,p |
| Splitting | 1.5 | NRk,sp |
| Concrete edge | 1.5 | VRk,c |
| Concrete pryout | 1.5 | VRk,cp |
## National Annex Variations
National Annexes may modify recommended values. Examples:
| Country | Modification |
| ------- | ------------------------------------------------ |
| Germany | Additional requirements for certain applications |
| UK | Generally follows recommended values |
| France | Some variations in combination factors |
Check your project's jurisdiction for applicable National Annex. Clariti defaults to EN 1992-4 recommended values.
## In Clariti
Clariti handles safety factors automatically:
1. **Product factors** — Uses ETA-specific γM where provided
2. **Standard factors** — Falls back to EN 1992-4 recommended values
3. **Transparency** — Shows all factors in expanded calculations
4. **Override option** — Advanced users can adjust factors if justified
All calculations display which factors were applied and their values, ensuring full traceability.
# Interface Overview
Source: https://docs.clariti.site/getting-started/interface-overview
Navigate the Clariti interface and understand each panel
This guide explains the main areas of the Clariti workspace and how to use them effectively.
## Dashboard Navigation
### Left Sidebar
The left sidebar provides quick access to your projects and designs:
* **Organization selector** — Switch between different company accounts (top of sidebar)
* **Search** — Quickly find projects and designs
* **Projects** — View all projects or filter by specific project
* **All designs** — View all designs across projects
* **Templates** — Access pre-configured design templates
* **Learn** — Access documentation and tutorials
### Projects View
The main content area displays your projects in a list view with the following information:
* **Name** — Project title
* **Created date** — When the project was created
* **Created by** — User who created the project or "Shared" status for organization-wide projects
* **Action buttons** — Share, star, and more options for each project
Click **Create new project** to start a new project. You can star important projects for quick access by clicking the star icon next to any project.
### All Designs View
The All designs view shows all designs across all your projects in a single list, making it easy to find and access any design quickly. This view displays:
* **Design name** — Title of the design
* **Project** — Which project the design belongs to
* **Created date** — When the design was created
* **Created by** — User who created the design or "Shared" status for organization-wide designs
### Templates
The Templates section provides pre-configured design templates to help you get started quickly with common anchor channel configurations. Select a template to create a new design with pre-filled parameters that you can customize for your specific needs.
## Design Interface
The Clariti workspace is divided into key areas:
The top bar provides:
* **Project name** — Click to access project settings
* **Design / Results tabs** — Switch between input mode and results view
* **Close** — Return to the project list
## Left Sidebar (Input Panels)
The left sidebar contains collapsible input panels:
### Product Selection
* **Channel Type** — Filter by channel family (e.g., All Channels)
### Applied Loads
* \*\*Position - \*\*from far left hand side of channel
* **Tension and shear forces**
### Lever Arms
* \*\*Lever Arm Length - \*\*length of arm in mm
* \*\*Degree of Restraint - \*\*between 1 and 2
### **Concrete Parameters**
* \*\*Edge Distances - \*\*c11, c12, e21, e22 all in mm. Select infinity by clicking on the ∞ icon.
* \*\*Member Thickness - \*\*concrete thickness in mm. Select infinity by clicking on the ∞ icon.
* \*\*Strength Class - \*\*concrete strength e.g. C50/60
* \*\*Crack Condition: \*\*cracked or uncracked
### **Reinforcement**
* \*\*Reinforcement Density: \*\*dense or widley spaced
* \*\*Splitting Reinforcement: \*\*Not PresentPresent
* \*\*Edge Reinforcement Type: \*\*none, straight edge, straight edge with stirups
Panels marked "Required" must be completed before running optimization.
## 3D Visualization (Center)
The main area displays your design in 3D:
### View Controls
Use the toolbar at the bottom of the viewport:
* **Camera presets** — Quick view angles (up, down, left, right, rotate)
* **Reset view** — Return to default perspective
### Export Options
Download 3D models directly from the toolbar:
* **DWG** — AutoCAD format
* **STP** — STEP file for CAD software
* **3DM** — Rhino 3D format
## Optimization Results Popup
After running optimization, a popup appears showing:
* **Ask AI** — Get AI assistance with your design
* **View Results** — Open the full results panel
## Bottom Controls
### Run Optimization
Click the **Run Optimization** button to calculate the optimal design based on your inputs.
### Design Edits / Chat Tabs
* **Design edits** — View history of changes made to the design, including parameter modifications and when they were made
* **Chat** — Access the AI assistant for help with your design. Ask questions about your configuration, troubleshoot issues, or get guidance on optimization
## Results Panel
Click **Results** in the top navigation or **View Results** in the popup to see:
### Summary
* Overall pass/fail status
* Utilisation percentage
* Key design values
### Detailed Calculations
Expandable sections showing:
* Reference clauses from EN 1992-4
* Input values and factors applied
* Step-by-step calculations
* Final resistance values
For the best experience, we recommend using Clariti on a desktop or laptop with a screen width of at least 1280px.
## Light vs Dark Mode
You can toggle between light and dark mode by clicking on the icon in the bottom left corner.
# Quick Start
Source: https://docs.clariti.site/getting-started/quick-start
Get up and running with Clariti in under 5 minutes
This guide walks you through specifying your first anchor channel connection in Clariti.
## Prerequisites
* A Clariti account ([sign up here](https://clariti.site/signup))
* Basic knowledge of structural loading and anchor channel concepts
* Your design loads (tension and/or shear forces)
## Your First Specification
1. **Log In and Create a Project**
After logging in, click **New Project** from the dashboard. Give your project a name and description.
2. **Create a Design**
Within your project, create a new design. You'll need to configure the channel:
* **Channel Family** — Select from CPRO38, CPRO50, CPRO52, or CPRO52S
* **Variant** — Choose the specific channel variant (e.g., CPRO38-1850)
* **Bolt Thread Size** — Select bolt size (e.g., M12)
3. **Define Applied Loads**
Enter the loads applied to the channel:
* **Position (mm)** — Distance from the far left end of the channel
* **Tension (kN)** — Applied tension force
* **Shear (kN)** — Applied shear force
* Click **+ Add Load** to add additional load points as needed
4. **Set Concrete Parameters**
Configure your concrete geometry:
* **Edge distances** — c₁₁, c₁₂, c₂₁, c₂₂
* **Member thickness** — depth of concrete element
Edge distances significantly affect capacity. Clariti will warn you if your geometry causes reductions.
5. **Set Concrete Strength**
Define the concrete properties:
* **Concrete strength class** (e.g., C30/37)
* **Concrete condition** — cracked or uncracked
6. **Configure Lever Arm (Optional)**
If your design includes a lever arm:
* **Lever Arm** — Enable or disable lever arm consideration
* **Degree of Restraint** — Value between 1 and 2 (1 = pinned, 2 = fully fixed)
7. **Configure Reinforcement Options**
Specify the reinforcement in your concrete element:
* **Reinforcement density** — widely spaced or closely spaced
* **Splitting reinforcement** — present or not
* **Edge reinforcement** — none, straight edge, or straight edge with stirrups
8. **Run Optimization**
Click the **Run Optimization** button to calculate the optimal design based on your inputs. After entering all required parameters (marked with \*), the optimization will run in seconds.
9. **Review Calculations**
A pop-up will display a summary of your calculation results showing:
* **Max Tension Utilisation** — Percentage and controlling failure mode
* **Max Shear Utilisation** — Percentage and controlling failure mode
* **Max Combined Utilisation** — Percentage for combined loading
Click **Ask AI** to get AI assistance with understanding your design, or **View Results** to see the full breakdown in the Results panel.
Use the **Chat** tab at the bottom of the screen to ask the AI assistant questions about your design at any time.
10. **Export Your Specification**
Once satisfied, export your work:
* **PDF Report** — full calculation package for checking/approval
* **3D Models** — download directly from the software
## What's Next?
* [Interface Overview](/getting-started/interface-overview) — Learn the Clariti interface in detail
* [Your First Project](/getting-started/first-project) — Detailed walkthrough of a complete project
Clariti performs design verification, not detailed design. You remain responsible for ensuring the design is appropriate for your specific application and complies with all relevant codes and standards.
# Exporting Reports
Source: https://docs.clariti.site/guides/exporting-reports
Generate professional documentation from your Clariti specifications
Clariti generates professional documentation for design verification, specification, and project records. This guide covers all export options.
## Export Options
Clariti offers several export formats:
| Format | Purpose | Audience |
| ---------- | ------------------------------ | ------------------------------- |
| PDF Report | Full calculation documentation | Checking engineers, authorities |
| DWG | Data integration | BIM, databases |
| STP | Data integration | BIM, databases |
| 3DM | Data integration | BIM, databases |
## PDF Calculation Report
### What's Included
The comprehensive PDF report contains:
**Cover Page:**
* Project name and reference
* Connection identifier
* Date and version
* Clariti branding and disclaimer
**Project Summary:**
* Concrete parameters (class, condition, exposure)
* Overall geometry summary
* List of connections in project
**Connection Details (per connection):**
* Geometry diagram with dimensions
* Load case summary table
* Selected product information
**Verification Results:**
* Summary pass/fail status
* Mode-by-mode utilization table
* Governing mode highlighted
**Detailed Calculations:**
* Full EN 1992-4 calculations
* Each failure mode expanded
* All factors shown with values
* Step-by-step equation evaluation
**Product Data:**
* ETA reference
* Key product parameters
* Manufacturer information
**Appendices:**
* Notation and symbols
* References to EN 1992-4 clauses
### Generating the Report
1. **Generate PDF**
Click **Download PDF Report**. Download starts automatically.
## Specification Text (coming)
### Purpose
Ready-to-use text for specification documents, schedules, and contract drawings.
### Format
```
ANCHOR CHANNEL SPECIFICATION
Product: CPRO 52/34 stainless steel 1.4404
Standard: EN 1992-4:2018
ETA: ETA-19/0881
Manufacturer: CFS
Embedment: 47 mm minimum
Material: Stainless steel grade 1.4404 (316)
Channel length: As shown on drawings
T-bolt: M10 grade A4-70 stainless
Torque: 25 Nm
Design loads verified:
Tension: 15.0 kN
Shear: 12.0 kN
Utilization: 78%
Concrete: C30/37 minimum strength
Condition: Cracked concrete assumed
Installation: Per manufacturer's instructions
and ETA requirements.
```
### Customization
Edit the generated text to match your project requirements:
* Add project-specific clauses
* Adjust formatting to house style
* Include cross-references to drawings
### BIM Integration
Use can download the channel in 3 formats; DWG, 3DM, STP. You can so that by clicking on the tabs below.
# Interpreting Results
Source: https://docs.clariti.site/guides/interpreting-results
Understanding and acting on Clariti's verification results
Understanding Clariti's results helps you make confident design decisions. This guide explains how to read and interpret the verification output.
## Results Popup
After running optimization, a popup appears immediately showing:
* **Optimization Complete** — Green checkmark indicates successful calculation
* **Max Tension Utilisation** — Percentage and controlling failure mode
* **Max Shear Utilisation** — Percentage and controlling failure mode
* **Max Combined Utilisation** — Percentage for combined loading
* **Ask AI** — Get AI assistance with understanding your design
* **View Results** — Open the full results panel
### Using Ask AI
Click **Ask AI** in the results popup to get instant help understanding your design. The AI assistant can:
* Explain why certain failure modes are controlling
* Suggest design modifications to improve utilisation
* Help troubleshoot designs that don't pass
* Clarify calculation methodology and standards compliance
You can also access the AI assistant at any time through the **Chat** tab at the bottom of the design interface.
## Results Overview
Clariti presents results at three levels:
1. **Summary** — Pass/fail with key metrics
2. **Mode breakdown** — Each failure mode's utilization
3. **Detailed calculation** — Full equations and values
## Summary Panel
### Overall Status
The primary indicator:
| Status | Meaning | Action |
| ------ | --------------------------- | ------------------------ |
| ✓ Pass | All checks satisfied | Proceed to specification |
| ✗ Fail | One or more checks exceeded | Redesign required |
### Utilization Indicator
The utilization bar shows:
* Percentage of capacity used
* Color coding (green/yellow/red)
* Governing mode highlighted
### Key Metrics
| Metric | What It Shows |
| -------------------- | --------------------------- |
| Overall utilization | Highest individual mode |
| Governing mode | Which failure type controls |
| Combined utilization | Interaction check result |
## Mode Breakdown
### Tension Modes
| Mode | What Fails | Key Factors |
| ------------- | -------------------- | ------------------------------------- |
| Steel failure | Anchor/channel steel | Steel grade, cross-section |
| Concrete cone | Concrete breakout | hef, fck, edges |
| Pullout | Anchor bearing | Product-specific, fck |
| Splitting | Concrete splitting | Thickness, edges, spacing |
### Shear Modes
| Mode | What Fails | Key Factors |
| ------------- | ------------------ | ------------------------ |
| Steel failure | Shear of steel | Steel grade, diameter |
| Concrete edge | Breakout to edge | Edge distance, direction |
| Pryout | Back-face breakout | Embedment depth |
### Combined Check
Interaction between tension and shear demands.
## Reading Utilization Values
### Comparing Modes
Look at the spread between modes:
**Example A — Balanced Design:**
```
Steel tension: 45%
Concrete cone: 68% ← Governing
Pullout: 52%
Splitting: 61%
```
All modes similar — well-balanced design.
**Example B — Single Mode Governing:**
```
Steel tension: 30%
Concrete cone: 92% ← Governing
Pullout: 35%
Splitting: 55%
```
One mode much higher — design limited by concrete. Consider:
* Larger embedment depth
* Supplementary reinforcement
* Higher concrete strength
When one mode dominates, address that specific limitation rather than simply selecting a larger channel.
## Warnings and Alerts
### Edge Distance Warnings
| Warning | Meaning | Action |
| -------------------- | --------------------- | -------------------- |
| c \< ccr | Edge causes reduction | Accept or increase c |
| c \< cmin | Below minimum | Must increase c |
### Spacing Warnings
| Warning | Meaning | Action |
| -------------------- | ------------------------ | -------------------- |
| s \< scr | Spacing causes reduction | Accept or increase s |
| s \< smin | Below minimum | Must increase s |
### Member Thickness Warnings
| Warning | Meaning | Action |
| -------------------- | -------------- | -------------------- |
| h \< hmin | Splitting risk | Increase h or verify |
## Detailed Calculation View
Click any mode to expand the full calculation.
### Calculation Structure
```
1. Reference clause (EN 1992-4 section)
2. Design equation
3. Input values
- Geometry
- Material properties
- Product data
4. Reduction factors (ψ values)
- Each factor with its calculation
- Source of each value
5. Characteristic resistance (Rk)
6. Partial factor (γM)
7. Design resistance (Rd)
8. Utilization (Ed/Rd)
```
### Tracing Values
Every value shows its source:
* **\[Input]** — Your entered value
* **\[ETA]** — Product data from approval
* **\[EN 1992-4]** — Standard reference
* **\[Calculated]** — Derived from other values
## Understanding Factor Reductions
### Area Ratios (Ac,N/A°c,N)
Reduced from 1.0 when:
* Edges are close (cone truncated)
* Multiple anchors (overlapping cones)
* Shallow members (depth limited)
### ψ Factors
| Factor | Reduces for |
| ---------------- | ------------------------------ |
| ψs,N | Close edges |
| ψre,N | No supplementary reinforcement |
| ψec,N | Eccentric loading |
| ψh,V | Shallow members (shear) |
| ψα,V | Load angle to edge |
### Cumulative Effect
Multiple factors multiply together:
```
NRd,c = N°Rk,c × (Ac,N/A°c,N) × ψs,N × ψre,N × ψec,N / γMc
```
If several factors are low, combined reduction is severe.
## Common Result Patterns
### Pattern 1: Edge-Limited Design
Symptoms:
* Concrete cone or edge failure governs
* Low ψs values
* Warning about edge distances
Solutions:
* Increase edge distance if possible
* Add edge reinforcement
* Select deeper embedment channel
### Pattern 2: Steel-Limited Design
Symptoms:
* Steel failure governs
* High utilization on steel modes
* Concrete modes have large margin
Solutions:
* Select higher strength channel
* Use larger profile
* Consider multiple T-bolts
### Pattern 3: Interaction-Limited Design
Symptoms:
* Individual modes OK
* Combined check fails
* Moderate tension + moderate shear
Solutions:
* Distribute loads (multiple T-bolts)
* Select larger channel
* Reduce combined loading
### Pattern 4: Splitting-Limited Design
Symptoms:
* Splitting governs
* Thin member warning
* Edge or spacing issues
Solutions:
* Increase member thickness
* Select shallower channel
* Increase edge distances
## Acting on Results
### When Design Passes
1. Review governing mode — understand the limitation
2. Check margin — is there room for variation?
3. Consider warnings — any coordination needed?
4. Document — export calculation report
### When Design Fails
1. Identify failing mode(s)
2. Understand the cause (geometry, loads, product)
3. Consider options:
* Different product
* Geometry adjustment
* Load redistribution
* Multiple fixings
4. Re-run verification
5. Iterate until satisfactory
Don't just select larger products blindly. Understanding why a design fails helps you find efficient solutions.
# Selecting a Channel
Source: https://docs.clariti.site/guides/selecting-channel
Guide to choosing the right anchor channel for your application
Selecting the appropriate anchor channel involves balancing capacity, cost, material, and practical considerations. This guide helps you make informed choices.
## Selection Criteria
When choosing an anchor channel, consider:
1. **Load capacity** — Must exceed design demands
2. **Material compatibility** — Match exposure conditions
3. **Geometric fit** — Profile must suit member thickness
4. **Availability** — Product accessible in your region
5. **Cost efficiency** — Appropriate for application
## Step 1: Determine Required Capacity
### Review Your Design Loads
From your structural analysis:
* NEd — Design tension (kN)
* VEd — Design shear (kN)
### Account for All Load Cases
Different load combinations may govern:
* Dead + live
* Dead + wind
* Seismic combinations
* Accidental cases
Enter all relevant load cases in Clariti. The tool identifies which case governs for each failure mode.
## Step 2: Match Material to Environment
### Exposure Classes
| EN 206 Class | Environment | Recommended Material |
| ------------ | ----------------- | ---------------------- |
| XC1 | Dry interior | HDG steel |
| XC2 | Wet, rarely dry | HDG steel or stainless |
| XC3 | Moderate humidity | Stainless steel |
| XC4 | Cyclic wet/dry | Stainless steel |
| XD/XS | Deicing/marine | High-grade stainless |
Don't mix materials in a connection. Galvanic corrosion occurs when dissimilar metals contact in the presence of moisture.
## Step 3: Check Geometric Compatibility
### Member Thickness
The concrete member must be thick enough for:
* Full embedment depth (hef)
* Cover to reinforcement
* Fire protection requirements
```
Required thickness ≥ hef + cover + margin
```
### Channel Profile Selection
| Profile | hef (mm) | Min. Thickness |
| ------- | ------------------- | -------------- |
| ATA40 | 81 | ≥ 90 mm |
| CPRO38 | 72 | ≥ 100 mm |
| ATA50 | 107 | ≥ 120 mm |
| CPRO50 | 99 | ≥ 130 mm |
| ATA52 | 157 | ≥ 170 mm |
| CPRO52 | 151 | ≥ 185 mm |
### Edge Distance Check
Compare your edge distances to critical values:
```
If c ≥ ccr,N = 1.5 × hef → No reduction
If c < ccr,N → Capacity reduced
```
Channels with larger hef require larger edge distances for full capacity.
## Step 4: Verify Selection
### Check All Failure Modes
Don't just look at overall utilization. Review each mode:
* Is one mode much higher than others?
* Are edge-related modes critical?
* Is steel or concrete governing?
### Review Warnings
Clariti flags potential issues:
* Close edge distances
* Spacing interactions
* Member thickness concerns
* Material recommendations
### Consider Constructability
* Can the channel be placed accurately?
* Is there reinforcement conflict?
* Can the T-bolt be accessed for tightening?
* Is the channel length practical?
## Special Situations
### High Tension, Low Shear
Focus on:
* Concrete cone capacity
* Embedment depth (larger hef helps)
* Supplementary reinforcement possibility
Consider deeper profile channels.
### High Shear Toward Edge
Focus on:
* Concrete edge capacity
* Edge distance (increase if possible)
* Edge reinforcement
Consider moving channel away from edge or adding reinforcement.
### Combined Loading
Focus on:
* Interaction equation
* Both tension and shear modes
* Multiple T-bolts to distribute load
Consider larger channels or multiple fixings.
### Limited Member Depth
Focus on:
* Shallow profile channels
* Splitting capacity
* Blow-out potential
ATA40 (min. thickness 90 mm) is suitable for shallow members.
# What is Clariti
Source: https://docs.clariti.site/introduction
An overview of the Clariti platform and how it helps design teams specify.
## Welcome
**Clariti** is an AI-powered specification tool for structural engineers and architects working with construction products. Clariti streamlines the process of specifying cast-in anchor channels by combining intelligent optimization with standards-compliant calculations.
## Supported Products
Clariti currently supports the following cast-in anchor channel systems:
| Channel Family | Description | ETA Reference |
| -------------- | ------------------------------------ | ------------- |
| CPRO38 | Light-duty channel | ETA-25/0222 |
| CPRO50 | Medium-duty channel | ETA-25/0222 |
| CPRO52 | Heavy-duty channel | ETA-25/0222 |
| CPRO52S | Heavy-duty channel (stainless steel) | ETA-25/0222 |
| ATA40 | Light-duty hot-rolled channel (HDG) | ETA-25/0429 |
| ATA50 | Medium-duty hot-rolled channel (HDG) | ETA-25/0429 |
| ATA52 | Heavy-duty hot-rolled channel (HDG) | ETA-25/0429 |
Each channel family includes multiple variants (e.g., CPRO38-1850, ATA50-550) with different dimensions and load capacities. Select the appropriate variant during design configuration based on your specific requirements.
For the latest product availability, visit [clariti.site](http://clariti.site)
### Key Benefits
* **Standards-compliant calculations** — Full calculation verification with transparent methodology
* **Intelligent optimization** — AI acts as an expert guide
* **Real-time 3D visualization** — See your connections in context before specifying
* **Instant documentation** — Generate professional specification reports automatically
## Getting Started
## Create Your Account
1. Sign up at [clariti.site](https://clariti.site) to access the specification tool.
2. **Start a New Project**
3. **Start a New Design**
Input your design loads and let Clariti suggest suitable channel options.
4. **Review and Export**
Verify the calculations, adjust if needed, and export your specification report.
New to anchor channel design? Start with our [Quick Start](/getting-started/quick-start) guide to see Clariti in action.
## Standards Coverage
Clariti currently supports design verification to:
* **EN 1992-4:2018** — Design of fastenings for use in concrete
## Need Help?
* Browse the [documentation](/getting-started/quick-start) for detailed guides
* Contact [support@clariti.site](mailto:support@clariti.site) for technical assistance