Skip to main content
This page provides technical specifications for anchor channel products available in Clariti. All values are sourced from manufacturer ETAs.

CPRO Series

Premium cast-in anchor channel system manufactured from high-strength stainless steel.

CPRO Profiles

ProfileWidth (mm)Height (mm)hef (mm)Weight (kg/m)
CPRO 38/233823471.8
CPRO 52/345234472.4
CPRO 72/487248633.6

CPRO Materials

GradeEN DesignationAISI EquivalentCorrosion Resistance
1.4404X2CrNiMo17-12-2316LHigh (marine)
1.4571X6CrNiMoTi17-12-2316TiHigh (stabilized)

CPRO Characteristic Values

CPRO 52/34 (Reference):
ParameterSymbolValueUnit
Steel tension resistanceNRk,s54.2kN
Steel shear resistanceVRk,s28.4kN
Pullout resistance (C20/25)NRk,p38.0kN
Pullout resistance (C50/60)NRk,p58.0kN

CPRO Installation Parameters

ParameterCPRO 38/23CPRO 52/34CPRO 72/48
Min. concrete cover20 mm25 mm30 mm
Min. member thickness100 mm100 mm120 mm
ccr,N71 mm71 mm95 mm
scr,N141 mm141 mm189 mm

ATA Series

Cost-effective hot-rolled anchor channel system.

ATA Profiles

ProfileWidth (mm)Height (mm)hef (mm)Weight (kg/m)
ATA 28/152815321.2
ATA 38/233823471.8
ATA 52/345234472.4

ATA Materials

GradeDescriptionCorrosion Resistance
HDGHot-dip galvanizedStandard (internal)
1.4301Stainless steel 304Good (external)

ATA Characteristic Values

ATA 52/34 HDG (Reference):
ParameterSymbolValueUnit
Steel tension resistanceNRk,s45.8kN
Steel shear resistanceVRk,s24.2kN
Pullout resistance (C20/25)NRk,p32.0kN
Pullout resistance (C50/60)NRk,p48.0kN

ATA Installation Parameters

ParameterATA 28/15ATA 38/23ATA 52/34
Min. concrete cover15 mm20 mm25 mm
Min. member thickness80 mm100 mm100 mm
ccr,N48 mm71 mm71 mm
scr,N96 mm141 mm141 mm

T-Bolt Specifications

T-Bolt Types

TypeThreadHeadMaterial Options
StandardM8, M10, M12T-head8.8, A2, A4
SerratedM8, M10, M12T-head serrated8.8, A4
Hammer headM8, M10, M12Hammer8.8, A2, A4

T-Bolt Capacities

ThreadGrade 8.8Grade A2-70Grade A4-70
M818.4 kN12.5 kN14.0 kN
M1029.2 kN19.6 kN22.0 kN
M1242.4 kN28.5 kN32.0 kN

Torque Values

ThreadGrade 8.8Stainless A4
M820 Nm18 Nm
M1025 Nm22 Nm
M1245 Nm40 Nm
Always use the torque values specified in the ETA. Overtightening can damage the channel or reduce capacity.

Critical Values Reference

Tension Factors

Profilek1 (cracked)k1 (uncracked)
All profiles8.912.7

Concrete Strength Factors

Strength Classfck (MPa)√fck
C20/25204.47
C25/30255.00
C30/37305.48
C35/45355.92
C40/50406.32
C45/55456.71
C50/60507.07

ETA References

All products in Clariti are covered by European Technical Assessments:
Product RangeETA NumberValidity
CPRO SeriesETA-19/0881Current
ATA SeriesETA-19/0882Current
ETA documents contain complete technical data. Clariti’s database is synchronized with current ETA values. For the authoritative source, refer to the original ETA document.

Profile Selection Guide

By Load Requirement

Approximate Load RangeRecommended Profile
NEd < 10 kNATA 28/15
NEd 10-20 kNATA/CPRO 38/23
NEd 20-35 kNATA/CPRO 52/34
NEd > 35 kNCPRO 72/48

By Application

ApplicationTypical ProfileNotes
Light servicesATA 28/15MEP hangers
Standard facadeCPRO 52/34Brackets, supports
Heavy loadsCPRO 72/48Large equipment
Thin slabsATA 28/15Shallow embedment